rev-fury
280
ICM
280
$72.95

   

This item usually ships: Same Day.


ICM280
REPLACES- UTEC: 1012-933D, GOODMAN: B18099-06, B18099-08, B18099-10 and B18099-13 B18099-13S HSI modules, TEXAS INSTRUMENTS 41F-5, WHITE-RODGERS 50T35-730 50T35-743

9 PLUG WIRING HARNESS INCLUDED

Description

ICM280 Furnace Control Board

  • Low cost, direct replacement board for Goodman, Janitrol, TI, White-Rodgers and UTEC
  • Microprocessor based design for precise timing
  • Functions with all 24 VAC thermostats
  • Diagnostic fault codes (blinking LED) for simple troubleshooting
  • Twining compatible with another ICM280
  • For 80+ and 90+ applications
  • 9-pin card slot connection and 9-pin Molex connector on board
  • UL recognized

Specifications

Environment:
Ambient Temperature
- Operating: -40ºF to 176ºF
- Storage: -40ºF to 185ºF
Humidity: 5% to 95% R.H. (non-condensing) @ +55ºF
Vibration: 13.8Hz @ 0.2 Gs for one hour in each orthogonal axis
Flame Speed: UL 94-VO rating

Electrical:
Voltage Range: Line (98 to 132 VAC) @ 60Hz
Ignitor: 5A @ 120 VAC
Cool Blower: 10A, 2 HP, 240 VAC
Heat: 5A, 240 VAC
Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas Valve: 1.5A @ 30 VAC

Timing:
Trial for Ignition: 7.0 seconds
- Ignition activation period = 5 seconds
- Flame establishing period = 2 seconds
Flame Failure Response Time: 0.8 seconds maximum
Inducer Pre-Purge Time: 1 Second
Inducer Post-Purge Time:
- 25 seconds 80% furnace
- 29 seconds 90% furnace
Ignitor Warm Up Time:
- 15 seconds, first trial
- 20 seconds, second and third ignition trials
Total Trials for Ignition: 3 (automatically reset after one hour)
Heat Blower on Delay: 30 seconds
Heat Blower Off Delays: 90, 120 and 150 seconds
Cool Blower on Delay: 5 seconds
Cool Blower Off Delay: 60 seconds

Status LEDs:
LED ON: No fault
OFF: Gas valve fault detected
1: Ignition failure (after 3 tries and start of soft lockout)
2: Pressure switch stuck closed
3: Pressure switch failed to close
4: Limit switch failed open
5: Flame present with gas valve output off
6: Brownout voltage
7: Fault twinning
Rapid Flashing: Wrong polarity of 120VAC and Neutral

Downloads

Sell Sheet Installation Guide

REPLACES: GOODMAN: B18099-06/08/10/13/13S, TEXAS INSTR: 41F-S, UTEC: 1012-933D, WHITE-RODGERS: 50T35-730, 50T35-743, ICM: ICM280

Search

Enter a Part Name, Description, or Keyword.

Tip 1: For partial keyword, please use wildcard *.
For example b2ta*
Tip 2: If you want to find a particular manufacturer, use the "Browse by Manufacturer" feature.

Call Us: (866) 321-4822