TJERNLUND MODEL IL IN-LINE DRAFT INDUCER PROVIDES POSITIVE DRAFT FOR SMOKEPIPE AND AIDS PROPER EXHAUST OF COMBUSTION GAS. Click Here For Additional Information.
VENT PIPE DIAMETER (IN.) 9 TO 18 VOLTAGE 115 AMPS 5.4 MOTOR HORSEPOWER 1/4 HEIGHT (IN.) 17 WIDTH (IN.) 14 3/4 DEPTH (IN.) 10 CUT OUT REQUIRED 4 1/4 X 14 3/4
Model #
Pipe Size In.
Gas Firing with Draft Hood
Gas Firing with Bar. Draft Control
Oil Firing with Bar. Draft Control
Electrial Data
Heater BTU Input
270° F Flue Gas
Heater BTU Input
390° F Flue Gas
Heater BTU Input
530° F Flue Gas
Volt
Hz
RPM
Watts
Amp.
Ther Prot.
S.P.
CFM
S.P.
CFM
S.P.
CFM
IL
9
1,460,000
.145
1010
1,970,000
.175
989
1,700,000
.180
900
115
60
1725
1/4hp
5.4
Yes
10
2,080,000
.170
1370
2,460,000
.185
1240
1,900,000
.180
1010
12
1,920,000
.160
1325
2,230,000
.182
1120
1,500,000
.170
789
14
1,840,000
.159
1270
1,470,000
.158
740
825,000
.135
453
115
60
1725
1/3hp
6.0
Yes
16
900,000
.120
620
650,000
.113
340
350,000
.095
184
18
650,000
.099
450
440,000
.095
220
200,000
.075
106
Parts List