rev-fury
322
ICM
322
$40.02

   

This item usually ships: Same Day.


Attachments:
Installation Guide
Heat pump defrost timer. Ultra low cost, Direct replacement for Carrier CES0130024-00, Time and temperature control, Outdoor fan and reversing valve relay integrated into design, High installed base. INPUT: Voltage: 18 to 30 VAC, Frequency: 50/60 Hz, Power Consumption: 1 watt max. OUTPUT: O, W2 Type: Relay, Form: DPST, N.O., Rating: 1 amp @ 30 VAC. T1,T2 Type: Relay, Form: SPST, N.O., Rating: 1 amp @ 30 VAC. OF1, OF2 Type: Relay, Form: SPST, N.C., Rating: 1/2 HP @ 240 VAC. TIME DELAYS: Defrost Time: Fixed 10 minutes ±5%. Interval Time between defrosts: Pin-selectable 30/50/90 minutes. Power on Reset Time: 500ms. Test time: short across test terminals reduces test time 256x.

ICM322

REPLACES- CARRIER: CES0130024-00, TRANE: CNT02904