rev-fury

ICM

We sell 294 items made by ICM. This page shows items 81 to 100.

323
ICM
323
More Details...

$37.22

   

This item usually ships: 3-5 Days.
DEFROST CONTROL, 30/60/90 MINUTES, LIKE ICM304 WITH B TERMINAL
324
ICM
324
More Details...

$62.48

   

This item usually ships: 3-5 Days.
Pin-selectable, replaces Goettl 305057
325HN
ICM
325HN
More Details...

$90.61

   

This item usually ships: Same Day.
Head Pressure Control (120-480 VAC). Integral heat pump bypass circuitry allows electonic bypass of speed control. Eliminates overshoots common to on/off and pressure switch controls. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature bypass, isolated 24 VAC supply. INPUT: Control 18-30 VAC, 50/60 Hz 1.8 VA maximum, Line input 120-480 VAC. OUTPUT: Maximum 10 amps, minimum 100 mA.
325HNV
ICM
325HNV
More Details...

$100.70

   

This item usually ships: 3-5 Days.
RoHS complaint design, High Voltage, Output: 120-600 VAC, temperature input
325K1
ICM
325K1
More Details...

$0.00
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K1: with ICM375 probe, 50°-80°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
325K2
ICM
325K2
More Details...

$0.00
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K2: with ICM376 probe, 70°-100°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
325K3
ICM
325K3
More Details...

$0.00
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K3: with ICM376 probe, 95°-120°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
326HC
ICM
326HC
More Details...

$0.00
Head Pressure Control (120,208/240 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: 120 or 208/240 VAC, Frequency: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
326HM
ICM
326HM
More Details...

$0.00
Head#W/HtPmpBypsW/Probe120/480. Output 120-240 VAC - OEM Mitsubishi.
326HM2
ICM
326HM2
More Details...

$114.25

   

This item usually ships: 3-5 Days.
Output: 120-240 VAC-OEM Mitsubishi (LAQS-AS3208)
326HN
ICM
326HN
More Details...

$101.62

   

This item usually ships: 3-5 Days.
RoHS complaint design, Output: 120-240 VAC, temperature input
327H
ICM
327H
More Details...

$0.00
Head Pressure Control (480 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: Voltage: 480 VAC. FREQUENCY: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
327HN
ICM
327HN
More Details...

$107.97

   

This item usually ships: 3-5 Days.
RoHS complaint design, Output: 480 VAC, temperature input
329
ICM
329
More Details...

$62.48

   

This item usually ships: 3-5 Days.
Pin-selectable, replaces Goettl 305023
330
ICM
330
More Details...

$113.36

   

This item usually ships: Same Day.
ICM330 Single-Phase Head Pressure Control
332
ICM
332
More Details...

$91.47

   

This item usually ships: 3-5 Days.
RoHS compliant design, Output: 120-600 VAC; temperature or pressure inputs
333
ICM
333
More Details...

$93.38

   

This item usually ships: 3-5 Days.
RoHS compliant design, Output: 120-600 VAC; dual temperature or dual pressure inputs
336
ICM
336
More Details...

$717.75

   

This item usually ships: Same Day.
The ICM336 is an application specific three-phase frequency inverter designed to regulate head pressure at low ambient conditions by varying the amount of airflow through the condenser. It helps to ensure sufficient pressure across the expansion valve and prevent costly downtime. Sensor Input Type: • Temperature • Pressure • 4-20 mA • 0-1OVCD. Sensor Temperature: •40°F to 140°F • 4°C to 60°C Pressure Set Point: • 20 to 420 psig Minimum Frequency: • 3 to 55Hz Maximum Frequency: • 8 to 60Hz Current Trip: • 4 to 24 Amps (adjustable) Operating Characteristics: • Input Voltage: 240 VAC • Maximum Operating Temperature: 70°C. Pressure Transducer (ICM380) (Optional): • 0 to 500 psi, 1/4” SAE Female Flare (w/ Schraeder Deflator), 6 ft. long. • Power Rating: 240 VAC 1-3 HP.
337
ICM
337
More Details...

$717.75

   

This item usually ships: Same Day.
The ICM337 is an application specific three-phase frequency inverter designed to regulate head pressure at low ambient conditions by varying the amount of airflow through the condenser. It helps to ensure sufficient pressure across the expansion valve and prevent costly downtime. Sensor Input Type: • Temperature • Pressure • 4-20 mA • 0-1OVCD. Sensor Temperature: •40°F to 140°F • 4°C to 60°C Pressure Set Point: • 20 to 420 psig. Minimum Frequency: • 3 to 55Hz Maximum Frequency: • 8 to 60Hz Current Trip: • 4 to 24 Amps (adjustable) Operating Characteristics: • Input Voltage: 480 VAC • Maximum Operating Temperature: 70°C. Pressure Transducer (ICM380) (Optional): • 0 to 500 psi, 1/4” SAE Female Flare (w/ Schraeder Deflator), 6 ft. long. • Power Rating: 480 VAC 1-5 HP.
340
ICM
340
More Details...

$18.11

   

This item usually ships: Same Day.
Condensation Control. Input: 18 to 30 VAC, Output: 24 VAC to thermostat/cooling control; 24 VAC to optional overflow LED
   

Page:  1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Search

Enter a Part Name, Description, or Keyword.

Tip 1: For partial keyword, please use wildcard *.
For example b2ta*
Tip 2: If you want to find a particular manufacturer, use the "Browse by Manufacturer" feature.

Call Us: (866) 321-4822