Head Pressure Control (120-480 VAC). Integral heat pump bypass circuitry allows electonic bypass of speed control. Eliminates overshoots common to on/off and pressure switch controls. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature bypass, isolated 24 VAC supply. INPUT: Control 18-30 VAC, 50/60 Hz 1.8 VA maximum, Line input 120-480 VAC. OUTPUT: Maximum 10 amps, minimum 100 mA.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K1: with ICM375 probe, 50°-80°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K2: with ICM376 probe, 70°-100°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K3: with ICM376 probe, 95°-120°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
Head Pressure Control (120,208/240 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: 120 or 208/240 VAC, Frequency: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
Head Pressure Control (480 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: Voltage: 480 VAC. FREQUENCY: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
The ICM336 is an application specific three-phase frequency inverter designed to regulate head pressure at low ambient conditions by varying the amount of airflow through the condenser. It helps to ensure sufficient pressure across the expansion valve and prevent costly downtime. Sensor Input Type: • Temperature • Pressure • 4-20 mA • 0-1OVCD. Sensor Temperature: •40°F to 140°F • 4°C to 60°C Pressure Set Point: • 20 to 420 psig Minimum Frequency: • 3 to 55Hz Maximum Frequency: • 8 to 60Hz Current Trip: • 4 to 24 Amps (adjustable) Operating Characteristics: • Input Voltage: 240 VAC • Maximum Operating Temperature: 70°C. Pressure Transducer (ICM380) (Optional): • 0 to 500 psi, 1/4” SAE Female Flare (w/ Schraeder Deflator), 6 ft. long. • Power Rating: 240 VAC 1-3 HP.
The ICM337 is an application specific three-phase frequency inverter designed to regulate head pressure at low ambient conditions by varying the amount of airflow through the condenser. It helps to ensure sufficient pressure across the expansion valve and prevent costly downtime. Sensor Input Type: • Temperature • Pressure • 4-20 mA • 0-1OVCD. Sensor Temperature: •40°F to 140°F • 4°C to 60°C Pressure Set Point: • 20 to 420 psig. Minimum Frequency: • 3 to 55Hz Maximum Frequency: • 8 to 60Hz Current Trip: • 4 to 24 Amps (adjustable) Operating Characteristics: • Input Voltage: 480 VAC • Maximum Operating Temperature: 70°C. Pressure Transducer (ICM380) (Optional): • 0 to 500 psi, 1/4” SAE Female Flare (w/ Schraeder Deflator), 6 ft. long. • Power Rating: 480 VAC 1-5 HP.