Manufacturer's Detail Page

Use this page to find products by manufacturer.

ICM

We sell 249 items made by ICM. This page shows items 61 to 80.

321
ICM
321
More Details...

$41.79

   

This item usually ships: Same Day.
Ultra Low Cost Heat Pump Defrost Timer. Voltage: 18 to 30 Vac, Frequency: 50/60 Hz, Power Consumption: 1 watt max.
322
ICM
322
More Details...

$40.02

   

This item usually ships: Same Day.
Heat pump defrost timer. Ultra low cost, Direct replacement for Carrier CES0130024-00, Time and temperature control, Outdoor fan and reversing valve relay integrated into design, High installed base. INPUT: Voltage: 18 to 30 VAC, Frequency: 50/60 Hz, Power Consumption: 1 watt max. OUTPUT: O, W2 Type: Relay, Form: DPST, N.O., Rating: 1 amp @ 30 VAC. T1,T2 Type: Relay, Form: SPST, N.O., Rating: 1 amp @ 30 VAC. OF1, OF2 Type: Relay, Form: SPST, N.C., Rating: 1/2 HP @ 240 VAC. TIME DELAYS: Defrost Time: Fixed 10 minutes ±5%. Interval Time between defrosts: Pin-selectable 30/50/90 minutes. Power on Reset Time: 500ms. Test time: short across test terminals reduces test time 256x.
325H
ICM
325H
More Details...

$105.41

   

This item usually ships: Same Day.
Head Pressure Control (120-480 VAC). Integral heat pump bypass circuitry allows electonic bypass of speed control. Eliminates overshoots common to on/off and pressure switch controls. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature bypass, isolated 24 VAC supply. INPUT: Control 18-30 VAC, 50/60 Hz 1.8 VA maximum, Line input 120-480 VAC. OUTPUT: Maximum 10 amps, minimum 100 mA.
325K1
ICM
325K1
More Details...

$184.40

   

This item usually ships: Same Day.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K1: with ICM375 probe, 50°-80°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
325K2
ICM
325K2
More Details...

$234.72

   

This item usually ships: Same Day.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K2: with ICM376 probe, 70°-100°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
325K3
ICM
325K3
More Details...

$183.45

   

This item usually ships: Same Day.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K3: with ICM376 probe, 95°-120°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
326HC
ICM
326HC
More Details...

$119.21

   

This item usually ships: Same Day.
Head Pressure Control (120,208/240 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: 120 or 208/240 VAC, Frequency: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
326HM
ICM
326HM
More Details...

$137.03

   

This item usually ships: Same Day.
Head#W/HtPmpBypsW/Probe120/480. Output 120-240 VAC - OEM Mitsubishi.
327H
ICM
327H
More Details...

$127.04

   

This item usually ships: Same Day.
Head Pressure Control (480 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: Voltage: 480 VAC. FREQUENCY: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
375
ICM
375
More Details...

$33.05

   

This item usually ships: Same Day.
Probe for use with ICM325K head pressure controls. Sensor probes with temperature range of- ICM375: 50-80°F (10-27°C).
377
ICM
377
More Details...

$32.55

   

This item usually ships: Same Day.
Probe for use with ICM325K head pressure controls. Sensor probes with temperature range of- ICM377: 95-120°F (35-49°C).
379
ICM
379
More Details...

$32.55

   

This item usually ships: Same Day.
Probe for use with ICM325H, ICM326H, ICM327H and ICM330 head pressure controls with optional heat pump bypass. Temperature range: 70-100° F (21-38° C).
380
ICM
380
More Details...

$111.62

   

This item usually ships: Same Day.
Optional pressure transducer for ICM330/ICM336/ICM337 3-phase head pressure controls. 0-500 PSI. OPT. # TRANS DUCE W/SHRAD FTNG
400
ICM
400
More Details...

$117.44

   

This item usually ships: Same Day.
THREE PHASE LINE VOLTAGE MONITOR. Monitors "front" and "back" sides of system. Universal voltage operation: 190-630 VAC. Knob-adjustable features and system set points. Protects against voltage unbalance, high/low voltage, phase loss, phase reversal, faulty power, incorrect sequencing and rapid short cycling. VOLTAGE: 190-630 VAC, FREQUENCY: 50/60 Hz, VOLTAGE UNBALANCE: Adjustable: 2-25%, CONTROL: 18-240 VAC, DELAY ON BREAK TIMER: .1-5 minutes, OUTPUT: Relay, SPDT, N.O.: 10 amps, N.C.: 6 amps.
402
ICM
402
More Details...

$42.58

   

This item usually ships: Same Day.
PHASE LOSS & REVERSAL PROTECTION. Low cost 3-phase protection for single side. Monitors for phase reversal, phase loss, unbalance % as a function of input voltage. Bright LED indicators for ON and FAULT. Universal 3-phase input: 190-600 VAC. Control voltage input 115, 208/240 VAC. Epoxy encapsulated for moisture protection. VOLTAGE: 190-600 VAC, FREQUENCY: 50/60 Hz, CONTROL: 115 or 208/240 VAC, OUTPUT: Relay, SPDT, N.O. 30 amps.
408
ICM
408
More Details...

$57.32

   

This item usually ships: Same Day.
PHASE LOSS & REVERSAL PROTECTION. Reliable 3-phase protection for single side. Monitors for phase reversal, phase loss, unbalance % and high/low voltage. Bright LED indicators for ON and FAULT. 8-pin plug-in mount. VOLTAGE: 190-480 VAC, FREQUENCY: 50/60 Hz, ADJUSTABLE DOB: .1-5 minutes, ADJUSTABLE DOM: .1-5 minutes, CONTACTS: 10 amps resistive @ 250 VAC.
409
ICM
409
More Details...

$70.05

   

This item usually ships: Same Day.
PHASE LOSS & REVERSAL PROTECTION. Reliable 3-phase protection for single side. Monitors for phase reversal, phase loss, unbalance % and high/low voltage. Bright LED indicators for ON and FAULT. DIN rail mount. VOLTAGE: 190-480 VAC, FREQUENCY: 50/60 Hz, ADJUSTABLE DOB: 1-5 minutes, ADJUSTABLE DOM: 1-5 minutes, CONTACTS 10 amps resistive @ 250 VAC.
412
ICM
412
More Details...

$101.90

   

This item usually ships: Same Day.
3-Phase, Plug-in line monitors, front side protection. Adjustable 400-480 VAC, fixed symmetry 8%, 8-pin plug-in.
415
ICM
415
More Details...

$102.91

   

This item usually ships: Same Day.
3-Phase, Plug-in line monitors, front side protection. Adjustable 208-240 VAC, adjustable symmetry 4-8%, 8-pin plug-in.
422
ICM
422
More Details...

$113.73

   

This item usually ships: Same Day.
3-Phase, Plug-in line monitors, front side protection. Adjustable 400-480 VAC, adjustable anti-short cycle timer, fixed symmetry 8%, 8-pin plug-in.
   