Heat pump defrost timer. Ultra low cost, Direct replacement for Carrier CES0130024-00, Time and temperature control, Outdoor fan and reversing valve relay integrated into design, High installed base. INPUT: Voltage: 18 to 30 VAC, Frequency: 50/60 Hz, Power Consumption: 1 watt max. OUTPUT: O, W2 Type: Relay, Form: DPST, N.O., Rating: 1 amp @ 30 VAC. T1,T2 Type: Relay, Form: SPST, N.O., Rating: 1 amp @ 30 VAC. OF1, OF2 Type: Relay, Form: SPST, N.C., Rating: 1/2 HP @ 240 VAC. TIME DELAYS: Defrost Time: Fixed 10 minutes ±5%. Interval Time between defrosts: Pin-selectable 30/50/90 minutes. Power on Reset Time: 500ms. Test time: short across test terminals reduces test time 256x.
Head Pressure Control (120-480 VAC). Integral heat pump bypass circuitry allows electonic bypass of speed control. Eliminates overshoots common to on/off and pressure switch controls. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature bypass, isolated 24 VAC supply. INPUT: Control 18-30 VAC, 50/60 Hz 1.8 VA maximum, Line input 120-480 VAC. OUTPUT: Maximum 10 amps, minimum 100 mA.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K1: with ICM375 probe, 50°-80°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K2: with ICM376 probe, 70°-100°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
Head Pressure Control (120-600 VAC). Features: hard start, low temperature bypass, isolated 24 VAC supply. Eliminates overshoots common to on/off and pressure switch controls. Controls one refrigerant circuit. ICM325K3: with ICM376 probe, 95°-120°. INPUT: Control 18-30 VAC, Line input 120-600 VAC, Frequency 50/60 Hz. OUTPUT: Maximum 10 amps, Minimum 100 mA.
Head Pressure Control (120,208/240 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: 120 or 208/240 VAC, Frequency: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
Head Pressure Control (480 VAC). Built in transformer eliminates cost, reduces installation time and simplifies wiring. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass. Ideal for line voltage air conditioning and refrigeration. INPUT: Voltage: 480 VAC. FREQUENCY: 50/60 Hz. OUTPUT: -Maximum: 10 amps -Minimum: 100 mA.
Probe for use with ICM325H, ICM326H, ICM327H and ICM330 head pressure controls with optional heat pump bypass. Temperature range: 70-100° F (21-38° C).
THREE PHASE LINE VOLTAGE MONITOR. Monitors "front" and "back" sides of system. Universal voltage operation: 190-630 VAC. Knob-adjustable features and system set points. Protects against voltage unbalance, high/low voltage, phase loss, phase reversal, faulty power, incorrect sequencing and rapid short cycling. VOLTAGE: 190-630 VAC, FREQUENCY: 50/60 Hz, VOLTAGE UNBALANCE: Adjustable: 2-25%, CONTROL: 18-240 VAC, DELAY ON BREAK TIMER: .1-5 minutes, OUTPUT: Relay, SPDT, N.O.: 10 amps, N.C.: 6 amps.
PHASE LOSS & REVERSAL PROTECTION. Low cost 3-phase protection for single side. Monitors for phase reversal, phase loss, unbalance % as a function of input voltage. Bright LED indicators for ON and FAULT. Universal 3-phase input: 190-600 VAC. Control voltage input 115, 208/240 VAC. Epoxy encapsulated for moisture protection. VOLTAGE: 190-600 VAC, FREQUENCY: 50/60 Hz, CONTROL: 115 or 208/240 VAC, OUTPUT: Relay, SPDT, N.O. 30 amps.