The ICM515 is an economical, dual voltage Surge Protector. Protects Against • Lightning power surges • Voltage surges from air conditioners, generators, motors… • Easy installation • Low cost, high performance • Weatherproof housing • Rugged, reliable. Surge Protector for • Refrigeration systems • Motors • Air conditioners • Appliances • Electronics. Service Voltage: • 120/240 volt. Single Phase Maximum Surge Current: • 24000 Amps Maximum Energy Dissipation: • 200 Joules. Installation Point: • Electrical Panel • Electrical Disconnect AC Protection Modes: • Line-Line, Line-Ground. Size • 1.75” X 1.62” X 0.75”.
OIL BURNER PRIMARY CONTROL. • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat • Solid state flame sensing circuit • LED on terminal strip indicates system lockout • Enclosed safety switch with external reset button • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing • C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required • Direct replacement for popular competitive models. Ignition Type Intermittent: Timing, Safety Switch • 15 seconds. Mounting Bracket • For mounting on a standard 4” X 4” junction box or direct mounting on burner housing Electrical Rating; Contacts (full load) • 7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor) • 44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions •4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104mm wide x 64mm deep. Temperature Range • -30°F to +130°F. Approvals • Underwriters Laboratories Inc.
OIL BURNER PRIMARY CONTROL. • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat • Solid state flame sensing circuit • LED on terminal strip indicates system lockout • Enclosed safety switch with external reset button • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing • C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required • Direct replacement for popular competitive models. Ignition Type Intermittent: Timing, Safety Switch • 30 seconds. Mounting Bracket • For mounting on a standard 4” X 4” junction box or direct mounting on burner housing Electrical Rating; Contacts (full load) • 7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor) • 44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions •4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104mm wide x 64mm deep. Temperature Range • -30°F to +130°F. Approvals • Underwriters Laboratories Inc.
OIL BURNER PRIMARY CONTROL. • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat • Solid state flame sensing circuit • LED on terminal strip indicates system lockout • Enclosed safety switch with external reset button • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing • C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required • Direct replacement for popular competitive models. Ignition Type Intermittent: Timing, Safety Switch • 45 seconds. Mounting Bracket • For mounting on a standard 4” X 4” junction box or direct mounting on burner housing Electrical Rating; Contacts (full load) • 7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor) • 44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions •4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104mm wide x 64mm deep. Temperature Range • -30°F to +130°F. Approvals • Underwriters Laboratories Inc.
SIMPLE COMFORT NON PROGRAMMABLE THERMOSTAT. HEAT ONLY, SINGLE STAGE WITH FAN: TERMINATIONS: R, C, W, G, HARDWIRED. Elegant design, Zoning system compatible, Adjustable differential, Large LCD temperature display, Hardwired, Precise temperature sensing, Easy access terminal block, Selectable Fahrenheit or Celsius, Compatible with standard 24-volt AC single stage heating systems, Integral five-minute anti-short cycle protection, Mercury-free, environmentally safe, Manual changeover. ELECTRICAL RATING: 24 VAC (18 to 30 VAC), 1 amp maximum per terminal, 4 amp maximum total load. TEMPERATURE CONTROL RANGE: 45°F to 90°F. ACCURACY: (± 1°F).
SIMPLE COMFORT NON-PROGRAMMABLE THERMOSTAT. 2-STAGE HEAT/1-STAGE COOL. TERMINATIONS: R, C, W1/0/B, Y, W2, E, G. HARDWIRED. legant design, Zoning system compatible, Adjustable differential, Large LCD temperature display, Precise temperature sensing, Easy access terminal block, Manual changeover, selectable Fahrenheit or Celsius, Mercury-free environmentally safe, Integral five-minute antishort cycle protection, Compatible with standard 24-volt AC Heating/Cooling systems. Electrical Rating: 24 VAC (18-30 VAC), 1 amp maximum per terminal, 4 amp maximum total load. Temperature Control Range: 45 degrees Fahrenheit to 90 degrees Fahrenheit. Accuracy (+) (-) 1 degree Fahrenheit.