100
|
| ICM |
More Details...
|
-
$15.56
-
This item usually ships: Same Day.
|
- For Anticipator Type Thermostats. Ideal for compressor staging/delaying the startup of motors and other devices, Works with anticipator-type thermostats, Simple 2-wire hookup,
Fixed timing, 18-240 VAC. INPUT: Voltage: 18-30 VAC, 1.5 amps, 15 amp inrush, TIME DELAYS: 3 Minute fixed time delay. CONTROL HAS 1/4" MALE QUICK CONNECT TERMINALS INSTEAD OF 6" WIRE LEADS.
|
|
|
100F
|
| ICM |
More Details...
|
-
$16.80
-
This item usually ships: Same Day.
|
- For Anticipator Type Thermostats. Ideal for compressor staging/delaying the startup of motors and other devices, Works with anticipator-type thermostats, Simple 2-wire hookup,
Fixed timing, 18-240 VAC. INPUT: Voltage: 18-30 VAC, 1.5 amps, 15 amp inrush, TIME DELAYS: 3 Minute fixed time delay. CONTROL HAS 6" WIRE LEADS INSTEAD OF 1/4" QUICK CONNECT TERMINALS.
|
|
|
101
|
| ICM |
More Details...
|
-
$15.56
-
This item usually ships: Same Day.
|
- For Anticipator Type Thermostats. Ideal for compressor staging/delaying the startup of motors and other devices, Works with anticipator-type thermostats, Simple 2-wire hookup,
Fixed timing, 18-240 VAC. INPUT: Voltage: 18-30 VAC, 1.5 amps, 15 amp inrush, TIME DELAYS: 5 Minute fixed time delay. CONTROL HAS 1/4" MALE QUICK CONNECT TERMINALS INSTEAD OF 6" WIRE LEADS.
|
|
|
101F
|
| ICM |
More Details...
|
-
$16.80
-
This item usually ships: Same Day.
|
- For Anticipator Type Thermostats. Ideal for compressor staging/delaying the startup of motors and other devices, Works with anticipator-type thermostats, Simple 2-wire hookup,
Fixed timing, 18-240 VAC. INPUT: Voltage: 18-30 VAC, 1.5 amps, 15 amp inrush, TIME DELAYS: 5 Minute fixed time delay. CONTROL HAS 6" WIRE LEADS INSTEAD OF 1/4" QUICK CONNECT TERMINALS.
|
|
|
102
|
| ICM |
More Details...
|
-
$12.99
-
This item usually ships: Same Day.
|
- DELAY ON MAKE TIMER. INPUT:For Anticipator Type Thermostats, Universal voltage operation. Higher 1.5 amp power rating. Knob-adjustable time delays. Works with anticipator-type thermostats. One model replaces many in field. VOLTAGE: 18-240 VAC, 1.5 AMP, 15 AMP INRUSH. TIME DELAYS: Adjustable delay: .03-10 minutes (1.8-600 seconds).
|
|
|
102F
|
| ICM |
More Details...
|
-
$14.36
-
This item usually ships: Same Day.
|
- DELAY ON MAKE TIMER: For Anticipator Type Thermostats, Universal voltage operation. Higher 1.5 amp power rating. Knob-adjustable time delays. Works with anticipator-type thermostats. One model replaces many in field. INPUT: Voltage: 18-240 VAC, 1.5 amp, 15 amp inrush. TIME DELAYS: Adjustable delay: .03-10 minutes (1.8-600 seconds). CONTROL HAS 6" WIRE LEADS INSTEAD OF 1/4" MALE QUICK CONNECT TERMINALS.
|
|
|
103
|
| ICM |
More Details...
|
-
$21.81
-
This item usually ships: Same Day.
|
- DELAY ON MAKE TIMER: Ideal For Ice Machine Applications. Highly precise digital timing. Switch-settable time delays. Ideal for ice machine applications. Universal voltage operation. Repeat accuracy .5% over voltage and temperature range. INPUT: Voltage: 18-240 VAC, 1 amp, 10 amp inrush, 40 mA holding current. TIME DELAYS: Swith-settable delays range from 1-1,023 seconds.
|
|
|
104
|
| ICM |
More Details...
|
-
$37.34
-
This item usually ships: Same Day.
|
- DELAY ON MAKE TIMER: Precise Digital Circuitry. Highly precise digital circuitry. High power, SPDT relay output. Input to output isolation. Works with anticipator-type thermostats. Repeat accuracy .5% over voltage and temperature range. 115 and 240 VAC models available. INPUT: Voltage: 18-30 VAC. OUTPUT: N.O.: 20 amps @ 240 VAC, N.C.: 10 amps @ 240 VAC, SPDT, 1 form C. Knob-adjustable time delay:10-1,000 seconds.
|
|
|
105
|
| ICM |
More Details...
|
-
$15.66
-
This item usually ships: Same Day.
|
- DELAY ON MAKE TIMER: Ideal For Compressor Staging. Low holding current. Low cost version of the ICM102 without the cooling anticipator circuitry. Ideal for compressor staging. Universal voltage operation. Knob-adjustable time delays. Simple 2-wire hookup. INPUT: Voltage: 18-240 VAC, 1.5 amps, 15 amp inrush, 10 mA holding current. TIME DELAYS: Adjustable: .03-10 minutes (1.8-600 seconds).
|
|
|
150
|
| ICM |
More Details...
|
-
$21.33
-
This item usually ships: Same Day.
|
- RANDOM START TIMER: UL 873 recognition as compressor controller. Compressor lockout/anti-short cycle timer. Integral random start capability. Random start delay is ideal for stagger starting multiple units. Reduces nuisance lockouts/service calls. Adjustable timing. 18-30 VAC. INPUT: Voltage: 18-30 VAC, 1 amp maximum, 40 mA minimum, 10 amp inrush, SPST, N.O. TIME DELAY: 6-600 seconds, Knob-adjustable, Voltage drop 1.5 V @ 1 amp. Compressor lockout/anti short cycle timer with random start.
|
|
|
150
|
| ICM |
More Details...
|
-
$21.33
-
This item usually ships: Same Day.
|
- RANDOM START TIMER: UL 873 recognition as compressor controller. Compressor lockout/anti-short cycle timer. Integral random start capability. Random start delay is ideal for stagger starting multiple units. Reduces nuisance lockouts/service calls. Adjustable timing. 18-30 VAC. INPUT: Voltage: 18-30 VAC, 1 amp maximum, 40 mA minimum, 10 amp inrush, SPST, N.O. TIME DELAY: 6-600 seconds, Knob-adjustable, Voltage drop 1.5 V @ 1 amp. Compressor lockout/anti short cycle timer with random start.
|
|
|
1501
|
| ICM |
More Details...
|
-
$46.44
-
This item usually ships: Same Day.
|
- OIL BURNER PRIMARY CONTROL. • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat • Solid state flame sensing circuit • LED on terminal strip indicates system lockout • Enclosed safety switch with external reset button • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing • C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required • Direct replacement for popular competitive models. Ignition Type Intermittent: Timing, Safety Switch • 15 seconds. Mounting Bracket • For mounting on a standard 4” X 4” junction box or direct mounting on burner housing Electrical Rating; Contacts (full load) • 7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor) • 44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions •4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104mm wide x 64mm deep. Temperature Range • -30°F to +130°F. Approvals • Underwriters Laboratories Inc.
|
|
|
1502
|
| ICM |
More Details...
|
-
$46.44
-
This item usually ships: Same Day.
|
- OIL BURNER PRIMARY CONTROL. • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat • Solid state flame sensing circuit • LED on terminal strip indicates system lockout • Enclosed safety switch with external reset button • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing • C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required • Direct replacement for popular competitive models. Ignition Type Intermittent: Timing, Safety Switch • 30 seconds. Mounting Bracket • For mounting on a standard 4” X 4” junction box or direct mounting on burner housing Electrical Rating; Contacts (full load) • 7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor) • 44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions •4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104mm wide x 64mm deep. Temperature Range • -30°F to +130°F. Approvals • Underwriters Laboratories Inc.
|
|
|
1503
|
| ICM |
More Details...
|
-
$45.10
-
This item usually ships: Same Day.
|
- OIL BURNER PRIMARY CONTROL. • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat • Solid state flame sensing circuit • LED on terminal strip indicates system lockout • Enclosed safety switch with external reset button • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing • C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required • Direct replacement for popular competitive models. Ignition Type Intermittent: Timing, Safety Switch • 45 seconds. Mounting Bracket • For mounting on a standard 4” X 4” junction box or direct mounting on burner housing Electrical Rating; Contacts (full load) • 7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor) • 44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions •4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104mm wide x 64mm deep. Temperature Range • -30°F to +130°F. Approvals • Underwriters Laboratories Inc.
|
|
|
151
|
| ICM |
More Details...
|
-
$36.99
-
This item usually ships: Same Day.
|
- RANDOM START TIMER: UL 873 recognition as compressor controller. Compressor lockout/anti-short cycle timer with random start feature plus: - Safety switch lockout - Remote thermostat reset. Reduces nuisance lockouts/service calls. Adjustable timing. 18-30 VAC. INPUT: Voltage: 18-30 VAC, 1 amp maximum, 40 mA minimum, 10 amp inrush. TIME DELAY: 6-600 seconds, Knob-adjustable.
|
|
|
151
|
| ICM |
More Details...
|
-
$36.99
-
This item usually ships: Same Day.
|
- RANDOM START TIMER: UL 873 recognition as compressor controller. Compressor lockout/anti-short cycle timer with random start feature plus: - Safety switch lockout - Remote thermostat reset. Reduces nuisance lockouts/service calls. Adjustable timing. 18-30 VAC. INPUT: Voltage: 18-30 VAC, 1 amp maximum, 40 mA minimum, 10 amp inrush. TIME DELAY: 6-600 seconds, Knob-adjustable.
|
|
|
1511
|
| ICM |
More Details...
|
-
$46.44
-
This item usually ships: Coming Soon!.
|
- OIL BURNER PRIMARY CONTROL - INTERRUPTED IGNITION. ICM's 1511 series Interrupted-duty Ignition Oil Primary Controls offers the basica control of the functions of the ICM 1500 series - including the patented energy transfer technology for added safety - with Interuppted Ignition for extended life and various post purge time delays. Direct replacement for popular competitive models. VALVE ON DELAY: 0 - 15 seconds (selectable). BURNER MOTOR OFF DELAY: 0 or 2, 4, 6 minutes (selectable). ALARMS CONTACTS: Yes.
|
|
|
1512
|
| ICM |
More Details...
|
-
$46.44
-
This item usually ships: Coming Soon!.
|
- OIL BURNER PRIMARY CONTROL - INTERRUPTED IGNITION. ICM's 1511 series Interrupted-duty Ignition Oil Primary Controls offers the basica control of the functions of the ICM 1500 series - including the patented energy transfer technology for added safety - with Interuppted Ignition for extended life and various post purge time delays. Direct replacement for popular competitive models. VALVE ON DELAY: 15 seconds. BURNER MOTOR OFF DELAY: 0 or 2, 4, 6 or 0.5, 2, 4, or 8 minutes (optional). ALARMS CONTACTS: Optional.
|
|
|
1513
|
| ICM |
More Details...
|
-
$46.44
-
This item usually ships: Coming Soon!.
|
- OIL BURNER PRIMARY CONTROL - INTERRUPTED IGNITION. ICM's 1511 series Interrupted-duty Ignition Oil Primary Controls offers the basica control of the functions of the ICM 1500 series - including the patented energy transfer technology for added safety - with Interuppted Ignition for extended life and various post purge time delays. Direct replacement for popular competitive models. VALVE ON DELAY: 15 seconds. BURNER MOTOR OFF DELAY: None. ALARMS CONTACTS: None.
|
|
|
1514
|
| ICM |
More Details...
|
-
$46.44
-
This item usually ships: 3-5 DAYS.
|
- OIL BURNER PRIMARY CONTROL - INTERRUPTED IGNITION. ICM's 1511 series Interrupted-duty Ignition Oil Primary Controls offers the basica control of the functions of the ICM 1500 series - including the patented energy transfer technology for added safety - with Interuppted Ignition for extended life and various post purge time delays. Direct replacement for popular competitive models. VALVE ON DELAY: None . BURNER MOTOR OFF DELAY: None. ALARMS CONTACTS: None.
|
|
| |
|